﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Academy of Medical Sciences of I.R. Iran</PublisherName>
      <JournalTitle>Archives of Iranian Medicine</JournalTitle>
      <Issn>1029-2977</Issn>
      <Volume>15</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2012</Year>
        <Month>03</Month>
        <DAY>01</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Prediction of Fetal Anemia by Different Thresholds of MCA-PSV and Delta-OD in First and Second Intrauterine Transfusions</ArticleTitle>
    <FirstPage>0</FirstPage>
    <LastPage>0</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Fatemeh</FirstName>
        <LastName>Rahimi-Sharbaf</LastName>
      </Author>
      <Author>
        <FirstName>Mamak</FirstName>
        <LastName>Shariat</LastName>
      </Author>
      <Author>
        <FirstName>Fatemeh</FirstName>
        <LastName>Mirzaie</LastName>
      </Author>
      <Author>
        <FirstName>Padideh</FirstName>
        <LastName>Dehghan</LastName>
      </Author>
      <Author>
        <FirstName>Ebrahim</FirstName>
        <LastName>Dastgardy</LastName>
      </Author>
      <Author>
        <FirstName>Khadijeh</FirstName>
        <LastName>Adabi</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">
      </ArticleId>
    </ArticleIdList>
    <History>
    </History>
    <Abstract>BACKGROUND: Our aim was to compare different thresholds of middle cerebral artery peak systolic velocity (MCA-PSV) and amniotic fluid delta optical density (Delta-OD) with fetal hemoglobin (Hb) during first and second intrauterine transfusions (IUT).  METHODS: We determined serial MCA-PSV and Delta-OD in 27 red blood cell alloimmunized fetuses who needed IUT. Before the second IUT, MCA-PSV was measured. The sensitivity and specificity of MCA-PSV and Delta-OD were calculated and compared with fetal hemoglobin levels.  RESULTS: From 27 fetuses, first time IUT MCA-PSV with a normal median value (MOM) cutoff of &gt; 1.29 detected 60% of the moderate and 100% of the severe anemia cases. MCA-PSV of MOM &gt; 1.5 detected none of the moderate and 93% of severe anemia cases. Delta-OD detected 50% of moderate anemic and 80% of severe anemic cases. At the second IUT, 91% of severe anemia cases were confirmed by MCA-PSV with MOM &gt; 1.5 whereas MCA-PSV with MOM &gt; 1.29 confirmed all cases. One case of moderate anemia was de-tected by MCA-PSV of MOM &gt; 1.29 and none were detected by MCA-PSV with MOM &gt; 1.5.  CONCLUSION: Different thresholds of MCA-PSV have higher sensitivity and specificity for detecting moderate and severe fetal anemia compared with Delta-OD. It also has a high sensitivity at the second IUT.</Abstract>
  </Article>
</ArticleSet>